range of product | Modicon TM3 Safety |
---|---|
product or component type | Safety module |
device short name | TM3SAF |
safety module application | For emergency stop and switch monitoring |
function of module | Emergency stop monitoring 1-channel wiring Emergency stop monitoring 2-channel wiring Monitoring of a movable guard with 2 switches and automatic start |
safety level | Can reach PL e/category 4 conforming to EN/ISO 13849-1: 2008 Can reach PL e/category 4 conforming to EN/ISO 13849-2: 2012 Can reach SILCL 3 conforming to EN/IEC 62061: 2005 Can reach SIL 3 conforming to EN/IEC 61508: 2010 |
safety reliability data | DC = 95 % conforming to EN/ISO 13849-1 PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A MTTFd = 500 years conforming to EN/ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A MTTFd = 85 years conforming to EN/ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A SFF = 95 % conforming to IEC 61508-1 HFT = 1 conforming to IEC 61508-1 Type = A conforming to IEC 61508-1 |
---|---|
synchronisation time between inputs | Unlimited |
connections - terminals | Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals |
output type | Relay instantaneous opening, 3 NO circuit(s), potential free |
number of safety circuits | 3 NO for relay instantaneous opening |
maximum switching voltage | 230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening) 24 V utilisation category DC-13 (relay instantaneous opening) |
[Us] rated supply voltage | 24 V - 15...20 % DC |
power consumption in W | 0.2 W at 5 V DC 3.6 W at 24 V DC |
input protection type | Internal, electronic |
[Uc] control circuit voltage | 24 V DC |
maximum cable distance between devices | 30 m |
breaking capacity | 360 VA holding AC-15 B300 relay output 3600 VA inrush AC-15 B300 relay output |
breaking capacity | 4 A 24 V 50 ms DC-13 relay output |
output thermal current | 6 A per relay for relay output |
[Ith] conventional free air thermal current | 18 A |
associated fuse rating | 4 A gG or gL for relay output conforming to EN/IEC 60947-5-1 6 A fast blow for relay output conforming to EN/IEC 60947-5-1 |
minimum output current | 10 mA for relay output |
output voltage | 10 V relay output |
maximum response time on input open | 40 ms |
[Ui] rated insulation voltage | 300 V (pollution degree 2) conforming to IEC 60647-5-1 |
[Uimp] rated impulse withstand voltage | 4 kV overvoltage category III conforming to IEC 60647-5-1 |
current consumption | 100 mA at 24 V DC external supply |
local signalling | 8 LEDs (green/red) for user |
electrical connection | Spring terminal |
standards | EN/ISO 13849-1:2008 EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012 |
product certifications | ANSI Haz Loc Class 1 Division 2 (pending) UL 61010-2-201 EAC TÜV RCM CSA Haz Loc Class 1 Division 2 (pending) CSA 61010-2-201 (pending) |
marking | EFUP 10 CE UL EAC RCM CSA TÜV |
electromagnetic compatibility | Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to EN 55011 Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to EN 55011 |
mounting support | Top hat type TH35-7.5 rail conforming to IEC 60715 Top hat type TH35-15 rail conforming to IEC 60715 wall mount using attached fasteners |
height | 94 mm |
depth | 73 mm |
width | 43.7 mm |
net weight | 0.19 kg |
standards | EN/ISO 13850 EN/IEC 60947-5-1 EN 1088/ISO 14119 EN 60204-1 EN/IEC 60947-1 |
---|---|
resistance to electrostatic discharge | 8 kV in air conforming to EN/IEC 61000-4-2 6 kV on contact conforming to EN/IEC 61000-4-2 |
resistance to electromagnetic fields | 10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3 |
resistance to magnetic fields | 30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8 |
resistance to fast transients | 3 kV for power lines (DC) (DC) conforming to EN/IEC 61000-4-4 2 kV for I/O lines conforming to EN/IEC 61000-4-4 |
surge withstand | 1 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 DC 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 DC |
resistance to conducted disturbances | 10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 |
electromagnetic emission | Radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3 Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3 |
ambient air temperature for operation | -10…55 °C horizontal installation |
ambient air temperature for storage | -25…70 °C |
relative humidity | 10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage) |
IP degree of protection | IP20 (terminals) conforming to EN/IEC 60529 |
pollution degree | 2 |
operating altitude | 0...2000 m |
storage altitude | 0…3000 m |
vibration resistance | +/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6 |
shock resistance | 15 gn for 11 ms conforming to IEC 60068-2-27 |
mechanical robustness | Bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27 |
Unit Type of Package 1 | PCE |
---|---|
Number of Units in Package 1 | 1 |
Package 1 Weight | 262.0 g |
Package 1 Height | 7.5 cm |
Package 1 width | 10.6 cm |
Package 1 Length | 12.5 cm |