Specifications

Main
range of productModicon TM3 Safety
product or component typeSafety module
device short nameTM3SAC
safety module applicationFor emergency stop and switch monitoring
function of moduleEmergency stop monitoring 1-channel wiring
Emergency stop monitoring 2-channel wiring
Monitoring of a movable guard with 2 switches and automatic start
safety levelCan reach PL d/category 3 conforming to EN/ISO 13849-1: 2008
Can reach PL d/category 3 conforming to EN/ISO 13849-2: 2012
Can reach SILCL 2 conforming to EN/IEC 62061: 2005
Can reach SIL 2 conforming to EN/IEC 61508: 2010
Complementary
safety reliability dataDC = 95 % conforming to EN/ISO 13849-1
PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A
PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A
MTTFd = 500 years conforming to EN/ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A
MTTFd = 85 years conforming to EN/ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A
SFF = 95 % conforming to IEC 61508-1
HFT = 1 conforming to IEC 61508-1
Type = A conforming to IEC 61508-1
synchronisation time between inputsUnlimited
connections - terminalsCaptive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² flexible without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.2...2 x 1.5 mm² solid without cable end 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 1 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals
Captive screw clamp terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.5 mm² flexible without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.14...2 x 0.75 mm² solid without cable end other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.25...2 x 0.34 mm² flexible with cable end, without bezel other terminals
Captive screw clamp terminals, removable terminal block 2 x 0.5 mm² flexible with cable end, with double bezel other terminals
output typeRelay instantaneous opening, 3 NO circuit(s), potential free
number of safety circuits3 NO for relay instantaneous opening
maximum switching voltage230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening)
24 V utilisation category DC-13 (relay instantaneous opening)
[Us] rated supply voltage24 V - 15...20 % DC
power consumption in W0.2 W at 5 V DC
3.6 W at 24 V DC
input protection typeInternal, electronic
[Uc] control circuit voltage24 V DC
maximum cable distance between devices30 m
breaking capacity360 VA holding AC-15 B300 relay output
3600 VA inrush AC-15 B300 relay output
breaking capacity4 A 24 V 50 ms DC-13 relay output
output thermal current6 A per relay for relay output
[Ith] conventional free air thermal current18 A
associated fuse rating4 A gG or gL for relay output conforming to EN/IEC 60947-5-1
6 A fast blow for relay output conforming to EN/IEC 60947-5-1
minimum output current10 mA for relay output
output voltage10 V relay output
maximum response time on input open40 ms
[Ui] rated insulation voltage300 V (pollution degree 2) conforming to IEC 60647-5-1
[Uimp] rated impulse withstand voltage4 kV overvoltage category III conforming to IEC 60647-5-1
current consumption100 mA at 24 V DC external supply (at state on)
local signalling6 LEDs (green/red) for user
electrical connectionScrew terminal
standardsEN/ISO 13849-1:2008
EN/ISO 13849-2:2012
EN/IEC 62061:2005
EN/IEC 61508:2010
EN/IEC 60947-5-1:2010
EN/IEC 61131-2:2007
EN/IEC 60204-1:2005
EN/IEC 60204-1:2009/A1
IEC 61010-1:2010
EN 50581:2012
product certificationsTÜV
CSA 61010-2-201 (pending)
CSA Haz Loc Class 1 Division 2 (pending)
RCM
ANSI Haz Loc Class 1 Division 2 (pending)
EAC
UL 61010-2-201
markingEFUP 10
RCM
CSA
UL
TÜV
CE
EAC
electromagnetic compatibilityElectrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2
Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2
Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3
Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8
Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to EN/IEC 61000-4-4
Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to EN/IEC 61000-4-4
1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5
Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6
Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to EN 55011
Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to EN 55011
mounting supportTop hat type TH35-7.5 rail conforming to IEC 60715
Top hat type TH35-15 rail conforming to IEC 60715
wall mount using attached fasteners
height94 mm
depth73 mm
width43.7 mm
net weight0.19 kg
Environment
standardsEN 1088/ISO 14119
EN/ISO 13850
EN/IEC 60947-1
EN 60204-1
EN/IEC 60947-5-1
resistance to electrostatic discharge8 kV in air conforming to EN/IEC 61000-4-2
6 kV on contact conforming to EN/IEC 61000-4-2
resistance to electromagnetic fields10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3
3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3
1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
resistance to magnetic fields30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
resistance to fast transients3 kV for power lines (DC) (DC) conforming to EN/IEC 61000-4-4
2 kV for I/O lines conforming to EN/IEC 61000-4-4
surge withstand1 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 DC
1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 DC
resistance to conducted disturbances10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
electromagnetic emissionRadiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3
Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3
ambient air temperature for operation-10…55 °C horizontal installation
ambient air temperature for storage-25…70 °C
relative humidity10…95 %, without condensation (in operation)
10…95 %, without condensation (in storage)
IP degree of protectionIP20 (terminals) conforming to EN/IEC 60529
pollution degree2
operating altitude0...2000 m
storage altitude0…3000 m
vibration resistance+/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6
shock resistance15 gn for 11 ms conforming to IEC 60068-2-27
mechanical robustnessBumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27
Packing Units
Unit Type of Package 1PCE
Number of Units in Package 11
Package 1 Weight279.0 g
Package 1 Height7.5 cm
Package 1 width10.6 cm
Package 1 Length12.5 c